*(Note: HFD Denotes Dual Chamber Filter System)

Unit of Measure

Specifications

Precoated Flow Rate (Filtering Capacity)

N/A 30,000 gph

Open Pumping Capacity

N/A 36,000 gph

Filtration Surface Area

N/A 300 ft²

Number of Filter Media

N/A 120

Filter Media Diameter

N/A 22 "

Sludge Holding Capacity

N/A 5.46 ft³

Length

N/A 104 "

Width

N/A 71 "

Height

N/A 59 "

System Connections Suction

N/A (2) 3" NPT (Female)

System Connections Discharge

N/A (2) 3" NPT (Female)
Motor (TEFC)1 N/A 10 HP Fybroc Series 1530 (Two Motors)

Pump Options

N/A FYBROC 1530 Fiberglass Pump - Standard

Slurry Tank Option

N/A WITH SLURRY TANK - Standard

Weight

N/A 2400 lbs

Features

Features

N/A
  • Flow rates to 30,000 GPH
  • Horizontal disc technology
  • Maximum surface area (1 sq. ft. per 100 GPH!)
  • Large sludge holding capacity
  • Superior corrosion resistance
  • FRP pump with choice of mechanical seals
  • Temperature to 190ºF (90ºC)
  • Low disposal cost
  • Choice of cellulose, carbon/cellulose or reusable polypropylene filter media
  • Powder coated steel frame with casters for easy handling
  • NEMA 4 water tight, corrosion resistant starter
  • Mechanical cover lifting device for easy access to filter pack
  • Bottom plate and lifting rod for quick change of disc stack standard

Filter

Filter

N/A Filter chambers are constructed of mild steel with hard rubber lining (3 mm) on the interior and corrosion resistant paint (2 coats) on the exterior.
A flanged tangential inlet is standard, along with a bottom outlet and drain.
Stainless steel eyebolts with handwheels hold the powder coated steel cover in place. The lifting device provides for mechanical movement of the cover for maintenance purposes. An air release valve positioned on the cover, is also used as the return line during pre-coating.
A pressure gauge (0-60 PSI) is supplied with a corrosion resistant guard.
Filter media suited for the application is placed between the rigid polypropylene filter discs. Filter media of various materials and micron ratings are available. Ten (10) micron cellulose is standard.
All systems are mounted on a powder coated structural steel frame with casters for easy handling.

Pump

Pump

N/A Fybroc fiberglass centrifugal pumps are standard. Mechanical seal options are single CRS- 35/B with silicon carbide faces or double water flush.

Slurry Tank Specifications

Slurry Tank Specifications

N/A Slurry tanks are mild steel construction with an interior of hard rubber (3 mm) and an exterior of corrosion resistant paint (2 coats). They are used to facilitate pre-coating and addition of activated carbon (if required), as well as solution make-up and priming of the pump. The slurry tank can also be used to store solution from the filter chamber during changing of media or maintenance. Pre-coating provides superior filtration and extends the life of the filter media.

Piping, Valves and Connections

Piping, Valves and Connections

N/A Piping, valves, and connections are all CPVC construction.
Suction of the pump is piped to permit flow from the solution tank, slurry tank, and the filter chamber.

X-Construction

X-Construction

N/A X-construction is used for more aggressive solutions such as acid copper, acid zinc, and acid tin. The filter chamber and slurry tank are outside rubber lined, the base and cover are powder coated and the pump shaft is titanium.

VD Lid Assembly

VD Lid Assembly

N/A VD Lid assembly is used to tighten down the disc stack verses the cover. (Standard)
  • 1 Motor availability (Specify completely with order):
    3 HP, 5 HP or 10 HP - 208, 230, 460, and 575 VAC (all 60 HZ, three-phase only)
    Fully-wired, liquid-tight motor starter is included for proper thermal and overcurrent protection