The Dynatronix by Process Technology - MicroStar is one of the most flexible product lines we offer. Designed to be used in almost any general metal finishing application. Simple to use, yet packed with features. DC, High Frequency Pulse (HFP) or Pulse Reverse, Air cooled, Benchtop, 5-30 amps, 20-40 volts, 4,000 watts.

Features:

*Microprocessor-based programmable controls
*Selectable current, voltage & cross-over regulation modes
*Rugged, environmentally-sealed, powder-coated enclosure
*Save/recall up to 10 different process steps
*Real Time Cycle Control
*Ampere Time Cycle Control
*Ampere Time Totalizer
*Error signals for over-temperature, locked fan rotor, output out-of-tolerance and power failure/brownout conditions
*Calibration capability through the control interface
*Digital input for inhibit/operator control
*FrontPanel+ Host Control Program for process set-up generation and process storage/data logging
*RS485 and USB ports for computer control
*Forced air cooled (larger models are water cooled)
*Straight DC and Choice of Low Frequency Pulse or High Frequency Pulse Output:
  - High Frequency Pulse (0-5000 Hz)
     *0 - 40 volts average (DC) or peak (pulsed) voltage
     *0 - 250 amps average current (or maximum DC current)
  - Low Frequency Pulse (0-200 Hz)
     *DC to 200 Hz pulses (at an 80% duty cycle)
     *Minimum Pulse Width: 4 milliseconds ON, 1 millisecond OFF (80% duty cycle)
     *Typical Pulse Rise Time: Less than 1500 milliseconds
     *Typical Pulse Fall Time: Less than 1000 milliseconds
Unit of Measure
Items
Dynatronix MicroStar DP

Dynatronix MicroStar DP Series Pulse Power Supplies

Dynatronix MicroStar DP

Dynatronix MicroStar DP Series Pulse Power Supplies

Dynatronix MicroStar DP

Dynatronix MicroStar DP Series Pulse Power Supplies

Dynatronix MicroStar DP

Dynatronix MicroStar DP Series Pulse Power Supplies

Dynatronix MicroStar DP

Dynatronix MicroStar DP Series Pulse Power Supplies
Output Voltage (DC) N/A 0-20 N/A 0-20 N/A 0-20 N/A 0-40 N/A 0-40
Max Avg/Peak Current (Amps) N/A 5/10 N/A 15/30 N/A 30/100 N/A 5/10 N/A 15/30
Voltmeter Resolution N/A *0.1/0.01
Amp Meter Resolution N/A 0.000 - 0.999 Amps (Average) in 0.001 Amp Increments 1.00 - 5-00 Amps (Average) in 0.01 Amp Increments N/A 0.000 - 2.999 Amps (Average) in 0.001 Amp Increments 3.00 - 15.00 Amps (Average) in 0.01 Amp Increments N/A 0.000 - 9.999 Amps (Average) in 0.001 Amp Increments 10.00 - 30.00 Amps (Average) in 0.01 Amp Increments N/A 0.000 - 0.999 Amps (Average) in 0.001 Amp Increments 1.00 - 5-00 Amps (Average) in 0.01 Amp Increments N/A 0.000 - 2.999 Amps (Average) in 0.001 Amp Increments 3.00 - 15.00 Amps (Average) in 0.01 Amp Increments
Cooling N/A Forced Air
Dimensions N/A 8.75" H x 17" W x 23" D N/A 8.75" H x 17" W x 23" D N/A 8.75" H x 17" W x 26" D N/A 8.75" H x 17" W x 23" D N/A 8.75" H x 17" W x 23" D
Voltage and Phase Required: N/A 110-120V, 50-60 Hz, 1 ph 208-240V, 50-60 Hz, 1 ph
Note1
N/A *Meter readings below 10 volts will show 0.01 Volt Resolution. Minimum Suggested Setting: 1% of peak current rating.
Line Regulation N/A +/- 1% of setting or +/- 0.1% of maximum rating, whichever is greater
Load Regulation N/A +/- 1% of setting or +/- 0.1% of maximum rating, whichever is greater
Digital Meter Accuracy N/A +/- 1% plus L.S.D.
Temperature Stability N/A 0.2% of peak rating after 15 minute warm up
Ripple N/A <1% RMS of maximum rated output voltage
Controller N/A FrontPanel+ Host Control Program for process set-up, process storage and data logging
Options N/A 19" Rack mount flange kit Analog interface board: 0-10V Analog interface board: 0-5V Analog interface board: 4-20mA Auxiliary totalizer with relay output to turn on/off pumps, mixer, etc. Master/Slave control - synchronize multiple units Ramp timer Recipe creation and storage Remote Control Panel (10' cable standard)
Warranty N/A 2 Years
Weight N/A 50.0 lbs
Manufacturer N/A Dynatronix