The Dynatronix by Process Technology - MicroStar is one of the most flexible product lines we offer. Designed to be used in almost any general metal finishing application. Simple to use, yet packed with features. DC, High Frequency Pulse (HFP) or Pulse Reverse, Air cooled, Benchtop, 0-30 amps, 20-40 volts, 4,000 watts.
Features:
*System Output: DC, High Frequency Pulse (HFP) or Pulse Reverse
*Small package size: linear technology
*Rugged, environmentally-sealed, powder-coated enclosure
*Patented Extended Operating Range
*Real Time Cycle Control
*Ampere Time Cycle Control
*Ampere Time Totalizer
*Constant current, constant voltage, and cross-over regulation modes
*High Frequency Pulse (HFP) Output Capability:
-DC to 5000 Hz pulses
*FrontPanel+ Host Control Program for process set-up generation and process storage/data logging
*RS485 and USB ports for computer control
*Electronic overload, over-temperature, and short circuit protection
*Save/recall up to 10 different process steps
*Convection cooled
Features:
*System Output: DC, High Frequency Pulse (HFP) or Pulse Reverse
*Small package size: linear technology
*Rugged, environmentally-sealed, powder-coated enclosure
*Patented Extended Operating Range
*Real Time Cycle Control
*Ampere Time Cycle Control
*Ampere Time Totalizer
*Constant current, constant voltage, and cross-over regulation modes
*High Frequency Pulse (HFP) Output Capability:
-DC to 5000 Hz pulses
*FrontPanel+ Host Control Program for process set-up generation and process storage/data logging
*RS485 and USB ports for computer control
*Electronic overload, over-temperature, and short circuit protection
*Save/recall up to 10 different process steps
*Convection cooled
Unit of Measure
Specifications
Output Voltage (DC) |
N/A 0-40 |
Max Avg/Peak Current (Amps) |
N/A 5/10 |
Voltmeter Resolution |
N/A *0.1/0.01 |
Amp Meter Resolution |
N/A 0.000 - 0.999 Amps (Average) in 0.001 Amp Increments 1.00 - 5-00 Amps (Average) in 0.01 Amp Increments |
Cooling |
N/A Convection |
Dimensions |
N/A 8.75" H x 17" W x 23" D |
Voltage and Phase Required: |
N/A 110-120V, 50-60 Hz, 1 ph 208-240V, 50-60 Hz, 1 ph |
Note1
|
N/A *Meter readings below 10 volts will show 0.01 Volt Resolution. Minimum Suggested Setting: 1% of peak current rating. |
Line Regulation |
N/A +/- 1% of setting or +/- 0.1% of maximum rating, whichever is greater |
Load Regulation |
N/A +/- 1% of setting or +/- 0.1% of maximum rating, whichever is greater |
Digital Meter Accuracy |
N/A +/- 1% plus L.S.D. |
Temperature Stability |
N/A 0.2% of peak rating after 15 minute warm up |
Ripple |
N/A <1% RMS of maximum rated output voltage |
Controller |
N/A FrontPanel+ Host Control Program for process set-up, process storage and data logging |
Options |
N/A 19" Rack mount flange kit Analog interface board: 0-10V Analog interface board: 0-5V Analog interface board: 4-20mA Auxiliary totalizer with relay output to turn on/off pumps, mixer, etc. Master/Slave control - synchronize multiple units Ramp timer Recipe creation and storage Remote Control Panel (10' cable standard) Trickle current |
Warranty |
N/A 2 Years |
Weight |
N/A 50.0 lbs |
Manufacturer |
N/A Dynatronix |
- 1