Print Back
  • SUPERIOR CHEMICAL RESISTANCE: Wide variety of materials available for use in heating or cooling applications for alkaline or acid solutions and rinse tanks. Check solution guide or consult with your chemical supplier for proper sheath material.
  • RUGGED CONSTRUCTION: Heavy wall, 20-gauge metal tubing available in 316 stainless steel and titanium.
  • 1" diameter tubing and 1" MNPT connection fittings standard.
  • OUTSTANDING PERFORMANCE: 2-inch thick, low profile design.
  • Every inch of coil surface is active exchange area.
  • LEAK-FREE OPERATION: Integral inlet and outlet manifolds for single point connections greatly reduces the potential for leaks and simplifies installation.
  • HIGH PRESSURE RATING: 100 PSI working pressure (steam or water).
  • SIZES: 4.6 square foot to 89.9 square foot of exchange area.
  • OPTIONS AVAILABLE (consult factory):
    • Mounting hangers.
    • Special sizes.
    • Vertical or horizontal configurations.
    • Heavier gauge tubing or pipe.
    • Special riser sizes, fittings, lengths, and configurations.
    • Anti-floatation weights recommended for high specific gravity or highly viscous solutions.
    • Zirconium, Hastelloy C® and other alloys available.
    • Fluoropolymer coatings for protection at solution/atmospheric interface.
    • Vacuum breakers.
    • Non-conductive isolator couplings.
    • High pressure ratings available (consult factory).
    Consult factory for inlet/outlet sizing assistance.
  • ORDERING EXAMPLE: T8G-24HS-BB-R30 - T=Titanium, 8 Tubes, G=Grid Style, 24" Length, H=Horizontal Configuration, S=Steam Usage, B=1" MNPT Inlet/Outlet, R=30" Risers.
Unit of Measure

Specifications

Number of Tubes

N/A 24

Depth

N/A 36 "914 mm

Length

N/A 132 "3353 mm

Width

N/A 36 "

Horizontal Exchange Area

N/A 67.8 ft²

Vertical Exchange Area

N/A 70.2 ft²

Material

N/A 316 Stainless Steel Hastelloy C® Titanium Zirconium

Configuration

N/A H = Horizontal V = Vertical

Service Conditions

N/A S = Steam W = Water

Inlet Connection

N/A A = 3/4" MNPT B = 1" MNPT C = 1-1/4" MNPT D = 1-1/2" E = 2" MNPT F = 1/2" FNPT G = 3/4" FNPT H = 1" FNPT J = 1/2" MNPT

Outlet Connection

N/A A = 3/4" MNPT B = 1" MNPT C = 1-1/4" MNPT D = 1-1/2" E = 2" MNPT F = 1/2" FNPT G = 3/4" FNPT H = 1" FNPT J = 1/2" MNPT

Riser Height

N/A -BR = bottom style coil, specify riser height no designator (horizontal style) = 12" riser (std) no designator (vertical style) = 8" riser (std) -R = specify custom riser height

Shipping Weight

N/A 59.0 Pound

Manufacturer

N/A Process Technology

Weight

N/A 119.0 lbs54.0 kg

Features and Benefits

Features and Benefits

N/A
  • SUPERIOR CHEMICAL RESISTANCE: Wide variety of materials available for use in heating or cooling applications for alkaline or acid solutions and rinse tanks. Check solution guide or consult with your chemical supplier for proper sheath material.
  • RUGGED CONSTRUCTION: Heavy wall, 20-gauge metal tubing available in 316 stainless steel and titanium.
  • 1" diameter tubing and 1" MNPT connection fittings standard.
  • OUTSTANDING PERFORMANCE: 2-inch thick, low profile design.
  • Every inch of coil surface is active exchange area.
  • LEAK-FREE OPERATION: Integral inlet and outlet manifolds for single point connections greatly reduces the potential for leaks and simplifies installation.
  • HIGH PRESSURE RATING: 100 PSI working pressure (steam or water).
  • SIZES: 4.6 square foot to 89.9 square foot of exchange area.
  • OPTIONS AVAILABLE (consult factory):
    • Mounting hangers.
    • Special sizes.
    • Vertical or horizontal configurations.
    • Heavier gauge tubing or pipe.
    • Special riser sizes, fittings, lengths, and configurations.
    • Anti-floatation weights recommended for high specific gravity or highly viscous solutions.
    • Zirconium, Hastelloy C® and other alloys available.
    • Fluoropolymer coatings for protection at solution/atmospheric interface.
    • Vacuum breakers.
    • Non-conductive isolator couplings.
    • High pressure ratings available (consult factory).

Note

Note1 N/A

Inlet and outlet connections must be sized to adequately handle water and steam volume requirements. Generally, larger inlet sizes are needed for grid coils larger than 33 sq. ft. (for steam) and 25 sq. ft. (for water).

  • 1