Single phase only. Guards recommended. This configuration is not recommended for electroless chemistry, phosphoric acid, or applications prone to sludge buildup. Longer vertical lengths and flexible risers available, consult factory.
Unit of Measure
Specifications
Series
N/AHXF Series
Watts
N/A500 W
Watt Density
N/A10 W/in²1.5 W/cm²
Volts
N/A240 V
Hot Zone
N/A6 "152 mm
Overall Length
N/A14 "356 mm
Diameter
N/A5 "127 mm
Std. Cold Zone
N/A8 "203 mm
Max. Cold Zone
N/A36 "914 mm
Material
N/AFluoropolymer
Phase
N/ASingle
Shipping Weight
N/A6.0 Pound
Options Available1
N/AComes Standard with Replaceable thermal protector: P1: for solutions up to 180°F (82°C). Resettable thermal protector: P2: for solutions up to 180°F (82°C). Resettable thermal protector: P3: for solutions up to 250°F (121°C). Resettable thermal protector: P8: for solutions up to 210°F (99°C).
Guards Recommended
N/AStandard guard is polypropylene. Fluoropolymer (PTFE) guards recommended for chromic acid and solutions exceeding 180º F (82ºC).
Guard Model Number
N/AHXF05-14G
Construction
N/AGround wire is welded to stainless steel sheath.