The Dynatronix by Process Technology - MicroStar Series is one of the most flexible product lines available. Multiple options for control interface. Switch mode design for small footprint. Rugged, environmentally-sealed, powder-coated enclosure. Simple to use, yet packed with features, MicroStar power supplies are designed to be used in almost any general metal finishing application. Models in the 0.1 to 3 ampere output range are ideally suited for laboratory or R&D applications. DC, Air coolded, Benchtop 0.1-3 amps, 12-100 volts, 100 watts.

Features:

*Multiple options for control interfaces
*Switch mode design for small footprint
*Rugged, environmentally-sealed, powder-coated enclosure
*Patented Extended Operating Range
*Real Time Cycle Control
*Ampere Time Cycle Control
*Ampere Time Totalizer
*Constant current, constant voltage, and cross-over regulation modes
*FrontPanel+ Host Control Program for process set-up generation and process storage/data logging
*RS485 and USB ports for computer control
*Electronic overload, over-temperature, and short circuit protection
*Save/recall up to 10 different process steps
*Convection cooled
Unit of Measure
Items
Dynatronix MicroStar DC

Dynatronix MicroStar DC Precise Power Supplies

Dynatronix MicroStar DC

Dynatronix MicroStar DC Precise Power Supplies

Dynatronix MicroStar DC

Dynatronix MicroStar DC Precise Power Supplies

Dynatronix MicroStar DC

Dynatronix MicroStar DC Precise Power Supplies
Output Voltage (DC) N/A 0-12 N/A 0-12 N/A 0-50 N/A 0-100
Output Current (Amps) N/A 0-1 N/A 0-3 N/A 0-1 N/A 0-1
Voltmeter Resolution N/A *0.1/0.01
Amp Meter Resolution N/A 0.0 - 99.9 Milliamps (Average) in 0.1 Milliamp Increments 100 - 1000 Milliamps (Average) in 1 Milliamp Increments N/A 0.0 - 299.9 Milliamps (Average) in 0.1 Milliamp Increments 300 - 3000 Milliamps (Average) in 1 Milliamp Increments N/A 0.0 - 299.9 Milliamps (Average) in 0.1 Milliamp Increments 300 - 3000 Milliamps (Average) in 1 Milliamp Increments N/A 0.0 - 299.9 Milliamps (Average) in 0.1 Milliamp Increments 300 - 3000 Milliamps (Average) in 1 Milliamp Increments
Cooling N/A Convection
Dimensions N/A 5.85" H x 12" W x 13.5" D N/A 5.85" H x 12" W x 13.5" D N/A 5.85" H x 12" W x 13.5" D N/A 7" H x 17" W x 22" D
Voltage and Phase Required: N/A 110-120V, 50-60 Hz, 1 ph 208-240V, 50-60 Hz, 1 ph
Note1
N/A *Meter readings below 10 volts will show 0.01 Volt Resolution.Minimum Suggested Setting: 1% of maximum rated output.
Line Regulation N/A +/- 1% of setting or +/- 0.1% of maximum rating, whichever is greater
Load Regulation N/A +/- 1% of setting or +/- 0.1% of maximum rating, whichever is greater
Digital Meter Accuracy N/A +/- 1% plus L.S.D.
Temperature Stability N/A 0.2% of peak rating after 15 minute warm up
Ripple N/A <1% RMS of maximum rated output voltage
Controller N/A FrontPanel+ Host Control Program for process set-up and process storage and data logging
Options N/A Analog interface board: 0-12V Analog interface board: 0-5V Analog interface board: 4-20mA Auxiliary totalizer with relay output to turn on/off pumps, mixer, etc. Ramp timer Recipe creation and storage Trickle current
Warranty N/A 2 Years
Weight N/A 15.0 lbs
Manufacturer N/A Dynatronix