T-DE Series, 1/8 Din Digital Thermostats Single Setpoint with 10 ft. Fluoropolymer (FEP) Sleeved Sensor
(2)Provides precise control for consistent plating and etch rates in most aqueous processes.
*12 amp full load max if operating a heater in series with a built-in thermal protector.
B-DE Series, Digital Combination Controls Single Phase with 10 ft. Fluoropolymer (FEP) Sleeved Sensor
(2)Provides precise control for consistent plating and etch rates in most aqueous processes.
Control consists of gasketed plastic enclosure, thermostat, and 30 amp power relay. Pre-wired outlets for plug-in heaters (16 amp max load).
C-DE Series, Digital Combination Controls Single or Three Phase with 10 ft. Fluoropolymer (FEP) Sleeved Sensor
(8)Provides precise control for consistent plating and etch rates in most aqueous processes.
/Asset/Process Tech DEcombo.jpgT-DLC Series, Digital Thermostats Single Phase with 10 ft. Fluoropolymer (FEP) Sleeved Sensor
(4)Provides precise control for consistent plating and etch rates in most aqueous processes.
*12 amp full load max if operating a heater with a thermal protector.
*(-V) (Mounted in 6x3 inch Plastic Enclosure)
B-DLC Series, Digital Combination Controls Single Phase
(2) Provides precise control for consistent plating and etch rates in most aqueous processes.Control consists of gasketed plastic enclosure, thermostat, and 30 amp power relay.
*12 amp full load max if operating a heater with a thermal protector. /Asset/Process Tech DLCcombo.png
C-DLC Series, Digital Combination Controls Single or Three Phase with 10 ft. Fluoropolymer (FEP) Sleeved Sensor
(8) Provides precise control for consistent plating and etch rates in most aqueous processes.Combination control consists of gasketed plastic enclosure, thermostat, 3 pole contactor and transformer. /Asset/Process Tech DLCcombo.png
T-DQ Series, 1/4 Din Digital Thermostats Dual Setpoint with 10 ft. Fluoropolymer (FEP) Sleeved Sensor
Provides precise control for consistent plating and etch rates in most aqueous processes.
*12 amp full load max if operating a heater with a built-in thermal protector.
*(-V) (Mounted in Plastic Enclosure) - Picture not Shown
B-DQ Series, Digital Combination Controls Single Phase with 10 ft. Fluoropolymer (FEP) Sleeved Sensor
(2) Provides precise control for consistent plating and etch rates in most aqueous processes.Control consists of gasketed plastic enclosure, thermostat, and 30 amp power relay. /Asset/Process Tech DQcombo.png
C-DQ Series, Digital Combination Controls Single or Three Phase with 10 ft. Fluoropolymer (FEP) Sleeved Sensor
(8)Provides precise control for consistent plating and etch rates in most aqueous processes.
Control transformer included.
T-DSL Series, 1/16 Din Digital Thermostats Dual Setpoint with 10 ft. Fluoropolymer (FEP) Sleeved Sensor
Provides precise control for consistent plating and etch rates in most aqueous processes. /Asset/Process Tech DSL.pngB-DSL Series, Digital Control/Power Relay Single Phase with 10 ft. Fluoropolymer (FEP) Sleeved Sensor
(2) Provides precise control for consistent plating and etch rates in most aqueous processes.Control consists of gasketed plastic enclosure, thermostat, and 30 amp power relay. /Asset/Process Tech DSLcombo.png
C-DSL Series, Digital Combination Controls Single or Three Phase with 10 ft. Fluoropolymer (FEP) Sleeved Sensor
(8) Provides precise control for consistent plating and etch rates in most aqueous processes.Combination control consists of gasketed plastic enclosure, thermostat, contactor and transformer. /Asset/Process Tech DSLcombo.png
Branch Fusing
BF Series Branch Fusing Enclosures
Convenient way to protect your circuits
Features:
* Provides safe alternative for multiple heaters wired into a single contactor.
* Saves time and money on heater/control installations.
* Can be used before or after contactor.
* Custom configurations to fit your process needs.
* Certifications: cULus.
Specifications:
* 0 up to 1000 amps
* Single or three phase configurations.
* 120 to 480 volts
* Adheres to UL requirements (508) and NEC codes.
Please call (847) 740-1599 for more help and assistance in requesting a Quote on this item. Thank you.
LC Series, Conductive Liquid Level Controls
(66)Provides automated control and consistent liquid levels in most conductive aqueous processes, waste treatment tanks and when leak detection is required.
Adds protection against damage and tank fires associated with low-level conditions.
Probe enclosure: vapor tight, flame retardant, polyproylene head with 10-foot (3m) flexible cord and quick connect plug for easy connection to remote circuitry.
Two probe units (LP-2): for single point control. Multi probe units (LP-3): for two-point control and refill/pump down applications. 4,5 or 6-probe devices for multiple level control applications, contact Sales at (847)-740-1599.
LCBA5 - Level switch electronics (only) mounted in plastic enclosure. 2-probe units
Electronic Assembly field selectable voltage 120/240V.
LCBE5 - Level switch electronics (only) mounted in plastic enclosure. 3-probe units
Electronic Assembly field selectable voltage 120/240V.
Control enclosure: gasketed NEMA 1, IP21 flame retardant, polypropylene box with stainless steel hardware.
*Specify probe material: (S) = STAINLESS STEEL, (T) = TITANIUM, (H) = HASTELLOY C, (G) = GRAPHITE (not field trimmable). (FLUOROPOLYMER (PTFE) COVERED STANDARD)
ORDERING EXAMPLE: (LP-3T36 + LCBE5) = 3 probe, titanium, 36” probe length, and level switch electronics (only) mounted in plastic enclosure. 3-probe units (order separately)
NOTE: LC Series Liquid Level Control probes purchased before October 1st, 2017 will require an adapter fitting to connect a new probe assembly to an older control or a newer control to an old probe assembly. See below for the adapter part number and price.
PRE OCTOBER 2017 CONTROL TO NEW LEVEL PROBE
PROBE ADAPTER
MODEL ITEM
NUMBER NUMBER
LP-2*** 13573
LP-3*** 13592
LP-4*** 13599
LP-5*** 13600
LP-6*** 13600
NEW CONTROL TO PRE OCTOBER 2017 LEVEL PROBE
CONTROL ADAPTER
MODEL ITEM
NUMBER NUMBER
LCBA5 13572
LCBE5 13582
2LCBJ5 13583
3LCBR5 13591
ESP Series, Capacitive Type Level Controls
Monitors liquid level from outside of plastic or non-metallic tanks.*For use in up to 1" thick tanks. /Asset/Photo-ESP.png
DTS Series, Digital Times
(2) Can be ordered as part of a combination temperature control assembly for an additional cost. /Asset/a1184.jpgW Series, Over The Side Thermowells
(27)Applications: Secures and protects temperature control sensors in tanks.
Materials of Construction:
* Quartz
* 304 stainless steel
* 316 stainless steel
* Titanium
* Fluoropolymer (PFA) covered 316 stainless steel
Capacities:
* OVER THE SIDE MODELS: 1/2 inch diameter tubing with mounting flange standard.
* THREADED MODELS: 1/2 inch MNPT standard.
Thermal Overload Protectors
(22)Protector 1, 2 and 3 Series
Thermal Overload Protection comes standard on all traditional style Process Technology over-the-side and bottom (L-shaped) industrial immersion heaters. Please check that these devices are properly installed to ensure safe operation of the heaters.
Alerts operators to identify and remedy the cause of overtemp conditions.
Features:
The Protector 1 Series
The Protector 1 overtemperature control system utilizes a heat sensitive fuse to detect overheat conditions. The protector, placed inside a thermowell, positioned in contact with the heater sheath, will cut power to the heater in the event of low liquid level.
The Protector 2 and 3 Series
The Protector 2 and Protector 3 systems provide the same reliable overtemperature protection as the Protector 1; however, the control systems feature a heat sensing thermostat. If the liquid level drops and the heater reaches a preset overheat temperature, the thermostat cuts power to the heater and an audible alarm activates. After filling the tank, the immersion heater can quickly be made operational by pushing the reset button on the control to restore power. Protector 3 is designed for flexible lead or high temperature fluoropolymer (PTFE) heater applications only. DO NOT wire P2, P6, P7 or P8 devices directly to power or heater load, as a dangerous short circuit will result with irreparable damage to the heater. Refer to wiring diagrams for proper installation.
Order replacement protectors by item number (below). P3 option not available on 8 and 9 kW elements. Lowest temperature replaceable style Protector standard unless otherwise designated.
RTD Temperature Sensors
(9)RTD Temperature Sensors
Resistance Temperature Detectors, or RTDs, are temperature sensors which utilize a material which has a predictable change in resistance as the sensor’s temperature is increased or decreased. RTDs are fragile, so it is placed inside a protective case to protect it. The RTD is further protected from the application and environment by dual wall heat shrink tubing.
Types of RTDs:
2 Wire – Used when high accuracy is not required, resistance of lead wire adds to resistance of the sensor. This configuration allows use of up to 100m of cable.
3 Wire - Used when high accuracy is required, resistance of lead wires cancel and do not add to resistance of the sensor. This configuration allows use of up to 600m of cable.
S Series, Brass Solenoid Valves
(12)Provides on/off control of water, steam, air, or gases in a variety of heating, cooling or fluid replenishing applications.
FEATURES
- Brass valve body with Buna-N seals for water service or Ethylene Propylene for steam service.
- Moisture resistant, epoxy encapsulated terminal enclosure rated for NEMA 1, 2, 3, 3S, 4 and 4X applications.
- Certifications: cULus.
SPECIFICATIONS
- Sizes: ½-inch through 2-inch FNPT.
- Two-way, normally closed valve available in 120 or 240 volts.
- Ambient temperature range: 32°F (0°C) to 125°F (52°C).
- Voltages: other AC and DC voltages available in 50 or 60 Hz, single phase only.
- Minimum pressure differential: 5 PSI.
- Minimum operating pressure: 10 PSI.
- Maximum pressure: Water Service: 125 PSI at 180°F(82°C); Steam Service: 50 PSI at 300°F(149°C).
NOTE: Always use a strainer with solenoid valves.
ST Series, Strainers
(7)Protects water and steam solenoid valves from particulate damage.
Provides on/off control of water, steam, air, or gases in a variety of heating, cooling or fluid replenishing applications.
FEATURES
- “Y” style cast bronze body with 20-mesh stainless steel screen.
SPECIFICATIONS
- Sizes: ½ inch through 2 1/2 inch FNPT.
- Working pressure:125 PSIG at 300°F (149°C).
- 20 mesh stainless screen.
NOTE: Always use a strainer with solenoid valves.
VB Series, Vacuum Breakers
Protects fluoropolymer heat exchangers from collapse damage due to vacuum conditions that often occur in steam lines.
FEATURES
- Brass body with stainless steel operating mechanism and EPR O-ring seat.
SPECIFICATIONS
- ½-inch FNPT only.
- Maximum steam service: 50 PSIG.
- Maximum temperature rating: 365°F (185°C).
- Can be installed in any position.
NOTE: One vacuum breaker should be installed immediately downstream from each fluoropolymer heat exchanger in the system.
IX Series, Coil Insulators/Isolators
(12)Protects metal heat exchangers and plating processes from stray voltage or current.
FEATURES
- Prevents seizing between metal lines.
- Dampens vibrations.
SPECIFICATIONS
- Sizes from ½-inch FNPT to 2-inch FNPT.
- Maximum steam service: 50 PSIG.
NOTE: Specify: S for 316 Stainless Steel, T for Titanium.