FlexKraft™ Air-Cooled Rectifiers provide premium DC power and performance for demanding industrial environments. Designed for 24/7 continuous operation under harsh conditions, the rectifiers include unique features such as Single and Multiple Outputs wth Optional Polarity Reversal, upgradeable power, self-serviceability and fail-safe operation.
With its modular design and an output ranging from 0-120V and 0-30,000A and a multitude of Control Options, we offer the flexibility to provide a best-fit solution to meet your most demanding process and application requirements.
The FlexKraft™ will help your business save money and become more competitive by reducing energy consumption and maintenance cost while increasing output and improving product quality. It’s not just another black box — it’s there to power your success.
With more than 80 years of experience, we won't let you down!
Click: FlexKraft Video Demo - Removal and Replacement of a Module.
Items |
FKA-1M FlexKraft Air-Cooled DC Rectifier (1 Module) (12V-600A, 15V-500A, 24V-300A, 30V-250A) |
FKA-2M FlexKraft Air-Cooled DC Rectifier (2 Module) (12V-1200A, 15V-1000A, 24V-600A, 30V-500A, 48V-300A, 60V-250A) |
FKA-3M FlexKraft Air-Cooled DC Rectifier (3 Module) (12V-1800, 15V-1500A, 24V-900A, 30V-750A) |
FKA-4M FlexKraft Air-Cooled DC Rectifier (4 Module) (12V-2400A, 15V-2000A, 24V-1200A, 30V-1000A, 48V-600A, 60V-500A) |
FKA-5M FlexKraft Air-Cooled DC Rectifier (5 Module) (12V-3000A, 15V-2500A, 24V-1500A, 30V-1250A) |
|||||
Alternating Current (AC) Supply Voltage | N/A 480 VAC /- 10%, 60 Hz, 3 Phase | N/A 480 VAC +/- 10%, 60 Hz, 3 Phase | N/A 480 VAC +/- 10%, 60 Hz, 3 Phase | N/A 480 VAC +/- 10%, 60 Hz, 3 Phase | N/A 480 VAC +/- 10%, 60 Hz, 3 Phase | |||||
Electromagnetic Compatibility (EMC) Conformity | N/A According to IEC 61000-6-4, Emissions, and IEC 61000-6-2, Immunity | |||||||||
Low Voltage Directive (LVD) Conformity | N/A According to IEC 50178 | |||||||||
Protection Class | N/A IP 32 | |||||||||
Power Factor at Rated Load | N/A >0.93 | |||||||||
Typical Efficiency at Rated Output | N/A 0.90 | |||||||||
Maximum Ambient Temperature | N/A 104 ºF | |||||||||
Derated Operation Ambient Temperature | N/A up to 122 ºF | |||||||||
Cooling | N/A Forced Air-Cooling | |||||||||
Maximum Relative Humidity | N/A 85 % | |||||||||
Control Precision (Voltage/Current) | N/A <+/- 1 % | |||||||||
Direct Current (DC) Ripple | N/A < 1% of rated output current at constant current mode in the entire range of regulation. | |||||||||
Regulation Range | N/A Stepless at constant voltage or current 0-100 % | |||||||||
Duty Ratio | N/A Designed for continuous operation at rated load up to 3300 ft altitude. | |||||||||
Protection | N/A Module Failure Open circuit Over-current Over-temperature Over-voltage Short circuit | |||||||||
Direct Current (DC) Output Voltage | N/A 0 to 12 V 0 to 15 V 0 to 24 V 0 to 30 V | N/A 0 to 12 V 0 to 15 V 0 to 24 V 0 to 30 V 0 to 48 V 0 to 60 V | N/A 0 to 12 V 0 to 15 V 0 to 24 V 0 to 30 V | N/A 0 to 12 V 0 to 15 V 0 to 24 V 0 to 30 V 0 to 48 V 0 to 60 V | N/A 0 to 12 V 0 to 15 V 0 to 24 V 0 to 30 V | |||||
Number of Power Modules | N/A 1 | N/A 2 | N/A 3 | N/A 4 | N/A 5 | |||||
Output Current at 0 to 12 Volt Direct Current (DC) Voltage | N/A 600 A | N/A 1200 A | N/A 1800 A | N/A 2400 A | N/A 3000 A | |||||
Output Current at 0 to 12 Volt Direct Current (DC) Voltage (Dual Power Supply) | N/A 2 x 300 A | N/A 2 x 600 A | N/A 2 x 900 A | N/A 2 x 1200 A | N/A 2 x 1500 A | |||||
Output Current at 0 to 15 Volt Direct Current (DC) Voltage | N/A 500 A | N/A 1000 A | N/A 1500 A | N/A 2000 A | N/A 2500 A | |||||
Output Current at 0 to 15 Volt Direct Current (DC) Voltage (Dual Power Supply) | N/A 2 x 250 A | N/A 2 x 500 A | N/A 2 x 750 A | N/A 2 x 1000 A | N/A 2 x 1250 A | |||||
Output Current at 0 to 24 Volt Direct Current (DC) Voltage | N/A 300 A | N/A 600 A | N/A 900 A | N/A 1200 A | N/A 1500 A | |||||
Output Current at 0 to 30 Volt Direct Current (DC) Voltage | N/A 250 A | N/A 500 A | N/A 750 A | N/A 1000 A | N/A 1250 A | |||||
Output Current at 0 to 48 Volt Direct Current (DC) Voltage | N/A | N/A 300 A | N/A | N/A 600 A | N/A | |||||
Output Current at 0 to 60 Volt Direct Current (DC) Voltage | N/A | N/A 250 A | N/A | N/A 500 A | N/A | |||||
Height | N/A 18 " | N/A 23 " | N/A 29 " | N/A 34 " | N/A 40 " | |||||
Weight | N/A 108 lbs | N/A 168 lbs | N/A 224 lbs | N/A 243 lbs | N/A 352 lbs | |||||
Footprint of Cabinet Width Including Busbars on the Rear Side | N/A 20 in | |||||||||
Footprint of Cabinet Depth Including Busbars on the Rear Side | N/A 24 in | |||||||||
Upgradable Output Power | N/A If your future power requirements change, don't buy a new rectifier, simply add more power modules to your FlexKraft or reconfigure your existing FlexKraft to meet your updated requirements. | |||||||||
Serviceable | N/A Simple design, easy accessibility, and self-diagnosing power modules makes the FlexKraft easy to trouble-shoot, service and repair. | |||||||||
Space-Saving | N/A Compact design and capability to stack several units in one tower makes efficient use of shop floor space. | |||||||||
High Power Factor | N/A >0.93 at rated load means no reative power penalty on your electricity bill and less strain on your local AC supply. | |||||||||
Ripple | N/A Less than 2% of rated output current in the entire range of regulation. Typical value at nominal output current is less than 0.2%. This standard feature is perfect for ripple sensitive processes. | |||||||||
Modular Design | N/A Any combination of power modules up to 120 VDC or 30,000 A can be supplied. | |||||||||
Options | N/A *Analogue interface with four inputs and four outputs galvanically isolated. Control and status signals 0-10 VDC or 0/4-20 mA. *Analogue/Digital interface. Two controls, and two status signals 0-10 VDC and two controls and two status signals 24 VDC. *Digital interface with four inputs and four outputs. Control signals 24 VDC. Status signals via voltage free relay contacts; contact data 24 VDC or 24 VAC. Standard configuration: On/Off, Block/Run, Power On and Alarm. *Electrically controlled AC breaker. *External reference shunt, 60 mV. *Polarity Reversal. *Raise/Lower function. *Remote control options: ControlKraft Touch or ControlKraft Digital *RS-232C interface control of one dual power supply. *Standard configuration: Iset, Uset, lact and Uact: 0-10 VDC. On/Off, Block/Run, Power On and Alarm as digital signals: 24 VDC. *Standard configuration: lset, Uset, lact and Uact: 4-20 mA | N/A *Analogue interface with four inputs and four outputs galvanically isolated. Control and status signals 0-10 VDC or 0/4-20 mA. *Analogue/Digital interface. Two controls, and two status signals 0-10 VDC and two controls and two status signals 24 VDC. *Digital interface with four inputs and four outputs. Control signals 24 VDC. Status signals via voltage free relay contacts; contact data 24 VDC or 24 VAC. Standard configuration: On/Off, Block/Run, Power On and Alarm. *Electrically controlled AC breaker. *External reference shunt, 60 mV. *Polarity Reversal. *Raise/Lower function. *Remote control options: ControlKraft Touch or ControlKraft Digital *RS-232C interface control of one dual power supply. *Standard configuration: Iset, Uset, lact and Uact: 0-10 VDC. On/Off, Block/Run, Power On and Alarm as digital signals: 24 VDC. *Standard configuration: lset, Uset, lact and Uact: 4-20 mA | N/A *Analogue interface with four inputs and four outputs galvanically isolated. Control and status signals 0-10 VDC or 0/4-20 mA. *Analogue/Digital interface. Two controls, and two status signals 0-10 VDC and two controls and two status signals 24 VDC. *Digital interface with four inputs and four outputs. Control signals 24 VDC. Status signals via voltage free relay contacts; contact data 24 VDC or 24 VAC. Standard configuration: On/Off, Block/Run, Power On and Alarm. *Electrically controlled AC breaker. *External reference shunt, 60 mV. *Polarity Reversal. *Raise/Lower function. *Remote control options: ControlKraft Touch or ControlKraft Digital *RS-232C interface for control of one power supply. *Standard configuration: Iset, Uset, lact and Uact: 0-10 VDC. On/Off, Block/Run, Power On and Alarm as digital signals: 24 VDC. *Standard configuration: lset, Uset, lact and Uact: 4-20 mA | N/A *Analogue interface with four inputs and four outputs galvanically isolated. Control and status signals 0-10 VDC or 0/4-20 mA. *Analogue/Digital interface. Two controls, and two status signals 0-10 VDC and two controls and two status signals 24 VDC. *Digital interface with four inputs and four outputs. Control signals 24 VDC. Status signals via voltage free relay contacts; contact data 24 VDC or 24 VAC. Standard configuration: On/Off, Block/Run, Power On and Alarm. *Electrically controlled AC breaker. *External reference shunt, 60 mV. *Polarity Reversal. *Raise/Lower function. *Remote control options: ControlKraft Touch or ControlKraft Digital *RS-232C interface for control of one power supply. *Standard configuration: Iset, Uset, lact and Uact: 0-10 VDC. On/Off, Block/Run, Power On and Alarm as digital signals: 24 VDC. *Standard configuration: lset, Uset, lact and Uact: 4-20 mA | N/A *Analogue interface with four inputs and four outputs galvanically isolated. Control and status signals 0-10 VDC or 0/4-20 mA. *Analogue/Digital interface. Two controls, and two status signals 0-10 VDC and two controls and two status signals 24 VDC. *Digital interface with four inputs and four outputs. Control signals 24 VDC. Status signals via voltage free relay contacts; contact data 24 VDC or 24 VAC. Standard configuration: On/Off, Block/Run, Power On and Alarm. *Electrically controlled AC breaker. *External reference shunt, 60 mV. *Polarity Reversal. *Raise/Lower function. *Remote control options: ControlKraft Touch or ControlKraft Digital *RS-232C interface for control of one power supply. *Standard configuration: Iset, Uset, lact and Uact: 0-10 VDC. On/Off, Block/Run, Power On and Alarm as digital signals: 24 VDC. *Standard configuration: lset, Uset, lact and Uact: 4-20 mA | |||||
Manufacturer | N/A KraftPowercon | |||||||||
|