Single phase only. Guards recommended. This configuration is not recommended for electroless chemistry, phosphoric acid, or applications prone to sludge buildup. Longer vertical lengths and flexible risers available, consult factory.

Unit of Measure

Specifications

Series

N/A HXF Series

Watts

N/A 3000 W

Watt Density

N/A 10 W/in²1.5 W/cm²

Volts

N/A 480 V

Hot Zone

N/A 10 "254 mm

Overall Length

N/A 23 "584 mm

Diameter

N/A 9 "229 mm

Std. Cold Zone

N/A 13 "330 mm

Max. Cold Zone

N/A 35 "889 mm

Material

N/A Fluoropolymer

Phase

N/A Single

Shipping Weight

N/A 13.0 Pound
Options Available1 N/A Comes Standard with Replaceable thermal protector: P1: for solutions up to 180°F (82°C). Resettable thermal protector: P2: for solutions up to 180°F (82°C). Resettable thermal protector: P3: for solutions up to 250°F (121°C). Resettable thermal protector: P8: for solutions up to 210°F (99°C).

Guards Recommended

N/A Standard guard is polypropylene. Fluoropolymer (PTFE) guards recommended for chromic acid and solutions exceeding 180º F (82ºC).

Guard Model Number

N/A HXF09-23G

Construction

N/A Ground wire is welded to stainless steel sheath.

Certifications

N/A
CE

CSA

UL Listed

Manufacturer

N/A Process Technology

Weight

N/A 13.0 lbs5.9 kg
  • 1 Consult factory