Print Back
The Dynatronix by Process Technology - MicroStar Series is one of the most flexible product lines available. Multiple options for control interface. Switch mode design for small footprint. Rugged, environmentally-sealed, powder-coated enclosure. Simple to use, yet packed with features, MicroStar power supplies are designed to be used in almost any general metal finishing application. Models in the 0.1 to 3 ampere output range are ideally suited for laboratory or R&D applications. DC, Air coolded, Benchtop 0.1-3 amps, 12-100 volts, 100 watts.

Features:

*Multiple options for control interfaces
*Switch mode design for small footprint
*Rugged, environmentally-sealed, powder-coated enclosure
*Patented Extended Operating Range
*Real Time Cycle Control
*Ampere Time Cycle Control
*Ampere Time Totalizer
*Constant current, constant voltage, and cross-over regulation modes
*FrontPanel+ Host Control Program for process set-up generation and process storage/data logging
*RS485 and USB ports for computer control
*Electronic overload, over-temperature, and short circuit protection
*Save/recall up to 10 different process steps
*Convection cooled
Dynatronix MicroStar DC
Unit of Measure
Items Dynatronix MicroStar DC
DC12-1 XR
Dynatronix MicroStar DC Precise Power Supplies
Dynatronix MicroStar DC
DC12-3 XR
Dynatronix MicroStar DC Precise Power Supplies
Dynatronix MicroStar DC
DC50-1 XR
Dynatronix MicroStar DC Precise Power Supplies
Dynatronix MicroStar DC
DC100-1 XR
Dynatronix MicroStar DC Precise Power Supplies
Output Voltage (DC) N/A 0-12 N/A 0-12 N/A 0-50 N/A 0-100
Output Current (Amps) N/A 0-1 N/A 0-3 N/A 0-1 N/A 0-1
Voltmeter Resolution N/A *0.1/0.01
Amp Meter Resolution N/A 0.0 - 99.9 Milliamps (Average) in 0.1 Milliamp Increments 100 - 1000 Milliamps (Average) in 1 Milliamp Increments N/A 0.0 - 299.9 Milliamps (Average) in 0.1 Milliamp Increments 300 - 3000 Milliamps (Average) in 1 Milliamp Increments N/A 0.0 - 299.9 Milliamps (Average) in 0.1 Milliamp Increments 300 - 3000 Milliamps (Average) in 1 Milliamp Increments N/A 0.0 - 299.9 Milliamps (Average) in 0.1 Milliamp Increments 300 - 3000 Milliamps (Average) in 1 Milliamp Increments
Cooling N/A Convection
Dimensions N/A 5.85" H x 12" W x 13.5" D N/A 5.85" H x 12" W x 13.5" D N/A 5.85" H x 12" W x 13.5" D N/A 7" H x 17" W x 22" D
Voltage and Phase Required: N/A 110-120V, 50-60 Hz, 1 ph 208-240V, 50-60 Hz, 1 ph
Note1 N/A *Meter readings below 10 volts will show 0.01 Volt Resolution.Minimum Suggested Setting: 1% of maximum rated output.
Line Regulation N/A +/- 1% of setting or +/- 0.1% of maximum rating, whichever is greater
Load Regulation N/A +/- 1% of setting or +/- 0.1% of maximum rating, whichever is greater
Digital Meter Accuracy N/A +/- 1% plus L.S.D.
Temperature Stability N/A 0.2% of peak rating after 15 minute warm up
Ripple N/A <1% RMS of maximum rated output voltage
Controller N/A FrontPanel+ Host Control Program for process set-up and process storage and data logging
Options N/A Analog interface board: 0-12V Analog interface board: 0-5V Analog interface board: 4-20mA Auxiliary totalizer with relay output to turn on/off pumps, mixer, etc. Ramp timer Recipe creation and storage Trickle current
Warranty N/A 2 Years
Weight N/A 15.0 lbs
Manufacturer N/A Dynatronix
  • 1