The Dynatronix by Process Technology - MicroStar is one of the most flexible product lines we offer. Designed to be used in almost any general metal finishing application. Simple to use, yet packed with features. Models in the 0.1 to 3 ampere output range are ideally suited for laboratory or R&D applications. DC, High Frequency Pulse (HFP) or Pulse Reverse, Air cooled, Benchtop, 0.1-3 amps, 0-10 volts, 30 watts

Features:

*System Ouput: DC, High Frequency Pulse (HFP) or Pulse Forward Only
*Small package size: linear technology
*Rugged, environmentally-sealed, powder-coated enclosure
*Patented Extended Operating Range
*Real Time Cycle Control
*Ampere Time Cycle Control
*Ampere Time Totalizer
*Constant current, constant voltage, and cross-over regulation modes
*High Frequency Pulse (HFP) Output Capability:
  - DC to 5000 Hz pulses
*FrontPanel+ Host Control Program for process set-up generation and process storage/data logging
*RS485 and USB ports for computer control
*Electronic overload, over-temperature, and short circuit protection
*Save/recall up to 10 different process steps
*Convection cooled
Unit of Measure
Items
Dynatronix MicroStar DuP

Dynatronix MicroStar DuP Series Pulse Power Supplies

Dynatronix MicroStar DuP

Dynatronix MicroStar DuP Series Pulse Power Supplies

Dynatronix MicroStar DuP

Dynatronix MicroStar DuP Series Pulse Power Supplies
Output Voltage (DC) N/A 0-10
Max Avg/Peak Current (Amps) N/A 0.1/0.3 N/A 1/3 N/A 3/6
Voltmeter Resolution N/A *0.1/0.01
Amp Meter Resolution N/A 0.0 - 100.0 Milliamps (Average) in 0.1 Milliamp Increments N/A 0.0 - 299.9 Milliamps (Average) in 0.1 Milliamp Increments 300 - 1000 Milliamps (Average) in 1 Milliamp Increments N/A 0.0 - 599.9 Milliamps (Average) in 0.1 Milliamp Increments 600 - 3000 Milliamps (Average) in 1 Milliamp Increments
Cooling N/A Convection
Dimensions N/A 5.85" H x 12" W x 13.5" D
Voltage and Phase Required: N/A 110-120V, 50-60 Hz, 1 ph 208-240V, 50-60 Hz, 1 ph
Note1
N/A *Meter readings below 10 volts will show 0.01 Volt Resolution. #Meter Resolution: Forward or Effective. Minimum Suggested Setting: 1% of peak current rating.
Line Regulation N/A +/- 1% of setting or +/- 0.1% of maximum rating, whichever is greater
Load Regulation N/A +/- 1% of setting or +/- 0.1% of maximum rating, whichever is greater
Digital Meter Accuracy N/A +/- 1% plus L.S.D.
Temperature Stability N/A 0.2% of peak rating after 15 minute warm up
Ripple N/A <1% RMS of maximum rated output voltage
Controller N/A FrontPanel+ Host Control Program for process set-up, process storage and data logging
Options N/A Analog interface board: 0-10V Analog interface board: 0-5V Analog interface board: 4-20mA Auxiliary totalizer with relay output to turn on/off pumps, mixer, etc. Ramp timer Recipe creation and storage Trickle current
Warranty N/A 2 Years
Weight N/A 15.0 lbs
Manufacturer N/A Dynatronix
  • 1