Print Back
The Dynatronix by Process Technology - MicroStar is one of the most flexible product lines we offer. Designed to be used in almost any general metal finishing application. Simple to use, yet packed with features. DC, High Frequency Pulse (HFP) or Pulse Reverse, Air cooled, Benchtop, 5-30 amps, 20-40 volts, 4,000 watts.

Features:

*System Output: DC, High Frequency Pulse (HFP) or Pulse Reverse
*Small package size: linear technology
*Rugged, environmentally-sealed, powder-coated enclosure
*Patented Extended Operating Range
*Real Time Cycle Control
*Ampere Time Cycle Control
*Ampere Time Totalizer
*Constant current, constant voltage, and cross-over regulation modes
*High Frequency Pulse (HFP) Output Capability:
  -DC to 5000 Hz pulses
*FrontPanel+ Host Control Program for process set-up generation and process storage/data logging
*RS485 and USB ports for computer control
*Electronic overload, over-temperature, and short circuit protection
*Save/recall up to 10 different process steps
*Convection cooled
Dynatronix MicroStar DPR
Unit of Measure
Items Dynatronix MicroStar DPR
DPR20-5-10 XR
Dynatronix MicroStar DPR Series Pulse Power Supplies
Dynatronix MicroStar DPR
DPR20-15-30 XR
Dynatronix MicroStar DPR Series Pulse Power Supplies
Dynatronix MicroStar DPR
DPR20-30-100 XR
Dynatronix MicroStar DPR Series Pulse Power Supplies
Dynatronix MicroStar DPR
DPR40-5-10 XR
Dynatronix MicroStar DPR Series Pulse Power Supplies
Dynatronix MicroStar DPR
DPR40-15-30 XR
Dynatronix MicroStar DPR Series Pulse Power Supplies
Output Voltage (DC) N/A 0-20 N/A 0-20 N/A 0-20 N/A 0-40 N/A 0-40
Max Avg/Peak Current (Amps) N/A 5/10 N/A 15/30 N/A 30/100 N/A 5/10 N/A 15/30
Voltmeter Resolution N/A *0.1/0.01
Amp Meter Resolution N/A 0.000 - 0.999 Amps (Average) in 0.001 Amp Increments 1.00 - 5-00 Amps (Average) in 0.01 Amp Increments N/A 0.000 - 2.999 Amps (Average) in 0.001 Amp Increments 3.00 - 15.00 Amps (Average) in 0.01 Amp Increments N/A 0.000 - 9.999 Amps (Average) in 0.001 Amp Increments 10.00 - 30.00 Amps (Average) in 0.01 Amp Increments N/A 0.000 - 0.999 Amps (Average) in 0.001 Amp Increments 1.00 - 5-00 Amps (Average) in 0.01 Amp Increments N/A 0.000 - 2.999 Amps (Average) in 0.001 Amp Increments 3.00 - 15.00 Amps (Average) in 0.01 Amp Increments
Cooling N/A Convection
Dimensions N/A 10.5" H x 17" W x 23" D N/A 10.5" H x 17" W x 23" D N/A 8.75" H x 17" W x 26" D N/A 8.75" H x 17" W x 23" D N/A 8.75" H x 17" W x 23" D
Voltage and Phase Required: N/A 110-120V, 50-60 Hz, 1 ph 208-240V, 50-60 Hz, 1 ph
Note1 N/A *Meter readings below 10 volts will show 0.01 Volt Resolution. Minimum Suggested Setting: 1% of peak current rating.
Line Regulation N/A +/- 1% of setting or +/- 0.1% of maximum rating, whichever is greater
Load Regulation N/A +/- 1% of setting or +/- 0.1% of maximum rating, whichever is greater
Digital Meter Accuracy N/A +/- 1% plus L.S.D.
Temperature Stability N/A 0.2% of peak rating after 15 minute warm up
Ripple N/A <1% RMS of maximum rated output voltage
Controller N/A FrontPanel+ Host Control Program for process set-up, process storage and data logging
Options N/A 19" Rack mount flange kit Analog interface board: 0-10V Analog interface board: 0-5V Analog interface board: 4-20mA Auxiliary totalizer with relay output to turn on/off pumps, mixer, etc. Master/Slave control - synchronize multiple units Ramp timer Recipe creation and storage Remote Control Panel (10' cable standard) Trickle current
Warranty N/A 2 Years
Weight N/A 50.0 lbs
Manufacturer N/A Dynatronix
  • 1