Maximum Rated Power |
N/A 60,000 Watts |
Number of Power Modules |
N/A 5 |
Output Voltage (DC) |
N/A 60 |
Output Current (Amps) |
N/A 1,000 |
Watts |
N/A 60,000 W |
Safe Operating Load Range |
N/A 0 - 100% of unit voltage and current rating |
Output Voltage Regulation |
N/A Max. +/- 0.5% of setting for 20-100% of unit rating Max. +/- 0.5% of unit rating for 3-20% of unit rating |
Output Current Regulation |
N/A Max. +/- 0.5% of setting for 10-100% of unit rating Max. +/- 0.5% of unit rating for 3-10% of unit rating |
Ripple, RMS Noise |
N/A Less than 0.3% RMS of unit rating (0-5kHz) |
Efficiency |
N/A 91% and higher at rated output |
Power Factor at Rated Load |
N/A 0.95 at rated output |
Enclosure |
N/A Powder coated aluminum |
Cooling |
N/A Forced Air |
Sealing |
N/A True Sealing with two 100% sealed air ducts |
Operating Temperature |
N/A 32 F - 104 F / 0 C - 40 C, indoor use only |
Storage Temperature |
N/A -4 F - 158 F / 20 C - 70 C |
Humidity |
N/A 20-80% RH non-condensing |
Maximum Installation Height |
N/A 2000m |
Dimensions |
N/A 25.25" H (3U) x 19" W x 26.1" D including 19" brackets and output busbars |
Voltage and Phase Required: |
N/A 380-480V +/-10%, 3ph, 50-60Hz |
Controller |
N/A M1F = Flush Mount, Rear exit M1T = Tabletop Mount, Rear exit M1W = Wall Mount, Bottom exit (std) |
Cable Length |
N/A 1 = 10 feet/3m (std) 2 = 25 feet/7.5m 3 = 50 feet/15m 4 = 100 feet/30m |
Options |
N/A AC = Advanced Process Control, Recipe, 200Hz AS = Analog Signals 0-10V or 4-20mA Blank = No options (std) DL = Data Logging EI = Ethernet/IP Communication |
Certifications |
N/A ETL listed to UL 61010-1 and CSA, C22.2#61010-1, CE certified |
Warranty |
N/A 2 Years |
Weight |
N/A 295.0 lbs |
Manufacturer |
N/A Dynatronix |
Note1 | N/A *Number of required power modules to be connected in parallel by customer. Each power module requires AC supply. Parallel management done by M-1 Controller. Communication cables included. DC Connection not included - Customer Supplied. |